FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource ValueSet/FHIR Server from package ch.fhir.ig.ch-rad-order#2.0.0-ballot (63 ms)

Package ch.fhir.ig.ch-rad-order
Type ValueSet
Id Id
FHIR Version R4
Source http://fhir.ch/ig/ch-rad-order/http://fhir.ch/ig/ch-rad-order/2.0.0-ballot/ValueSet-ch-rad-order-caveat-device.html
Url http://fhir.ch/ig/ch-rad-order/ValueSet/ch-rad-order-caveat-device
Version 2.0.0-ballot
Status active
Date 2024-05-17T11:21:51+00:00
Name ChRadOrderCaveatDevice
Title Caveat Device
Experimental False
Realm ch
Authority hl7
Description Definition for Caveat Device Value Set in the context of CH RAD-Order.
Copyright CC0-1.0

Resources that use this resource

No resources found


Resources that this resource uses

CodeSystem
http://snomed.info/sct SNOMED CT (all versions)
http://snomed.info/sct SNOMED codes used in this IG
http://snomed.info/sct SNOMED CT Canada Immunizations


Narrative

Note: links and images are rebased to the (stated) source

This value set includes codes based on the following rules:


Source

{
  "resourceType" : "ValueSet",
  "id" : "ch-rad-order-caveat-device",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>This value set includes codes based on the following rules:</p><ul><li>Include codes from <a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a> where concept is-a 397578001 (Device in situ (finding))</li><li>Include these codes as defined in <a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href=\"http://snomed.info/id/2667000\">2667000</a></td><td>Absent (qualifier value)</td></tr><tr><td><a href=\"http://snomed.info/id/373068000\">373068000</a></td><td>Undetermined (qualifier value)</td></tr></table></li></ul></div>"
  },
  "url" : "http://fhir.ch/ig/ch-rad-order/ValueSet/ch-rad-order-caveat-device",
  "version" : "2.0.0-ballot",
  "name" : "ChRadOrderCaveatDevice",
  "title" : "Caveat Device",
  "status" : "active",
  "date" : "2024-05-17T11:21:51+00:00",
  "publisher" : "HL7 Switzerland",
  "contact" : [
    {
      "name" : "Juerg P. Bleuer",
      "telecom" : [
        {
          "system" : "url",
          "value" : "https://www.hl7.ch"
        }
      ]
    }
  ],
  "description" : "Definition for Caveat Device Value Set in the context of CH RAD-Order.",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "urn:iso:std:iso:3166",
          "code" : "CH"
        }
      ]
    }
  ],
  "copyright" : "CC0-1.0",
  "compose" : {
    "include" : [
      {
        "system" : "http://snomed.info/sct",
        "filter" : [
          {
            "property" : "concept",
            "op" : "is-a",
            "value" : "397578001"
          }
        ]
      },
      {
        "system" : "http://snomed.info/sct",
        "concept" : [
          {
            "code" : "2667000",
            "display" : "Absent (qualifier value)"
          },
          {
            "code" : "373068000",
            "display" : "Undetermined (qualifier value)"
          }
        ]
      }
    ]
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.